Venturi and orifice meter experiment report. Venturi Meter And Orifice Plate 2019-02-20

Venturi and orifice meter experiment report Rating: 4,5/10 141 reviews

Essay about Venturi Meter

venturi and orifice meter experiment report

The inlet hose was attached from the bench regulating valve to the inlet of P6103. Measurement of fluid flow by means of pressure differential devices, Part 1: Orifice plates, nozzles, and Venturi tubes inserted in circular cross-section conduits running full. It was hypothesized that the greater the stronger the concentration gradient, the faster the rate of diffusion would be. The latter method is subject to greater error in calibration for absolute flows, but is sensitive for estimating slight changes in the rate of flow and does not require the use of an anticoagulant. The poem is built of four stanzas quatrain , each consisting of four lines.

Next

Calibration of Orifice & Venturi Meter

venturi and orifice meter experiment report

W 1996 principle of continuity state that the decrease in the area of the flowing fluid will increase the velocity of the flowing fluid. Given that both the velocity and piezometer head are constant over each of the sections considered, we might assume that flow to be one-dimensional so that the velocity and the piezometric head vary only in the direction of the tube length. A simple schematic of the meter used can be seen below in Figure 3. All group members were present and actively partook of the experiment which was conducted in the Fluid Mechanics lab on 7th September, 2011. Note the position of the dial when it is on one edge of the jet.

Next

Flow Meter Experiment

venturi and orifice meter experiment report

The items that were in series had. Slim Fit Black Stretch Jeans 500 Rs : 8. The pressure recovery is much better for the venturi meter than for the orifice plate. It should be noted that the Ho may vary during the time interval and this vary should be noted for uncertainty purposes. This lab aided students in observing kinematics by giving them a visual graph to look at from experiments previously performed.


Next

Green Mechanic: VENTURI METER AND ORIFICE PLATE LAB REPORT

venturi and orifice meter experiment report

Reading through the text of the song silently first is necessary for studying any song but more time and special attention is needed for songs like Du bist wie eine Blume, which is in a foreign language, German. With a well-calibrated marked glass tube, the level of the float becomes a direct measure of flow rate The venturi meter consists of a venturi tube and a suitable differential pressure gauge. TheoryThe operating principles of these various meters need to be developed in order to meaningfully compare their performance. Given such parameters the poet installs some sort of relaxation in the reader maybe even in himself , in order to make the subject - the beating - more readable, and lessening the effect of the drunkness and the beatings, making his father more human. In choked flow the mass flow rate will not increase with a further decrease in the downstream pressure environment. As described in the analytical method this needs to be an average diameter of the jet by measuring dout and din. The meter is trecet iamb stressed unstressed - three times per line.

Next

Flow Meter Experiment

venturi and orifice meter experiment report

Reasons for a low percent Recovery for Phthalic Acid and Naphthalene. Figure 2: Illustration of the secondary flows and vena contracta that occur in an orifice meter. Introduction Laboratory Lab reports are the most frequent document written by engineering student. Flow from the orifice was derived by measuring the time taken to fill the measuring tank between predetermined levels. After heating the salt crystal is called as anhydrous, which. Water is allowed to flow through the meter at different rates ranging from zero to the maximum and the corresponding pressure differences shown in the manometer are noted.

Next

Venturi Meter And Orifice Plate

venturi and orifice meter experiment report

For the following equations state 1 is located at M and state 0 is located at N in the schematic. The problem it is trying to explain is, how does table salt affect the boiling temperature of water? For our lab we took a total of eight measurements of different Ho values. Analytical Method In order to complete the objective for this lab there are a series of equations that must be derived from some basic physics equations such as the conservation of mass and energy. Abstract: The acceleration of objects dropped from about 2 meters was found in order to derive the Reynolds Number. Care was handled with the reading of the manometer because only slight changes occur; a keen eye from the group member was needed. As we have seen from our findings in this lab, such a rapid rate of urbanization affects. Once the level has settled the Ho value should be recorded and the tank can be filled to a volume of 15 liters.

Next

Venturi Meter And Orifice Plate

venturi and orifice meter experiment report

Thus it is prudent to make use of orifice plates during testing period and get Venturi meters prepared to be used for real time application. Wall Conducted on: September 17, 2009 Submitted on : September 24, 2009 Abstract: In this lab students experimented with light emitting diodes. This will ensure that the level in the tank remains steady while the measurements are being made. According to the laws governing fluid dynamics, a fluid's velocity must increase as it passes through a constriction to satisfy the principle of continuity, while its pressure must decrease to satisfy the principle of conservation of mechanical energy. The slope m that was used in Equation 17 was taken from the plot Figure 8 below which shows the relationship between the piezometer tube height and the volumetric flow rate.

Next

Venturi Meter And Orifice Plate

venturi and orifice meter experiment report

The second, the orifice meter, is a device used for measuring the rate of flow of a fluid through a pipe. To account for these sources of error a discharge coefficient is introduced into the calculation. One or both surface usually has a spherical curve. The venturi tube has a converging portion, a throat and a diverging portion as shown in the figure below. The Cu and Cc are assumed to be constant throughout the experiment of changing Ho values.

Next